Ref: 1200 Série - Standard

Low profile precision load cell | ±1.5 to ±9000 kN

  • High-resistance low profile load cell
  • Measuring range: ±5 kN to ± 9000 kN
  • Non-linearity: ±0.04%
  • Repeatability: ± 0.01%
  • Compensation of all transverse efforts
  • Low deflection
  • Temperature sensitivity < 0.0015% / °C
  • Measurement in tension/compression or compression only
  • Overload protection: 150% of FSO
  • Signal Output : 2 to 4 mV/V depending on the version
  • Operating temperature : -55 to 90°C
  • optional double or triple bridges

Download the product sheet

?
Lead time : 1-8 weeks

Presentation

High-capacity, high-performance load cells

The 1200 series force transducers meet the most demanding requirements for reliability and performance. Thanks to a design with low sensitivity to transverse loads, this force transducer is particularly well suited to applications, machines and test benches using hydraulic, pneumatic or electric actuators. Measuring ranges are from ±1.5 kN to ±9 MN.

Design

The design of the 1200 series transducers is the result of 50 years of continuous improvement. The choice of gauges, construction, manufacturing and calibration know-how enable us to achieve an accuracy of ± 0.04% of full scale, very high repeatability (< 0.01%) and stability over time (static accuracy: 0.04%). The construction is also virtually insensitive to eccentric (< 0.1% / cm) and transverse (< 0.25%) forces, and very robust, with 150% overload protection.

Operating temperature is -55 to 90°C. Calibration is temperature-compensated between -10 and 45°C.

Specifications

  • Measurement: tension/compression (12x0) or compression only (12x1, 12x3)
  • Bridge power supply: 1-20 VDC
  • Bridge resistance: 350 Ohm
  • Overload protection: 150%
Model Measuring Range Measurement Nonlinearity Hysteresis Arrow Output Weight Plan
1210 ±1.5 / ±2.5 / ±5 / ±10 kN T&C ± 0.04% ± 0.03% 0.03 mm 2.0 mV/V 0.7 kg Plan
1210 ±25 / ±50 kN T&C ± 0.04% ±0.04% 0.03 mm 4.0 mV/V 1.5 kg Plan
1211 0-5 / 0-10 kN Compression ± 0.03% ± 0.03% 0.03 mm 2.0 mV/V 0.7 kg Plan
1211 0-25 / 0-50 kN Compression ± 0.04% ± 0.04% 0.05 mm 4.0 mV/V 1.5 kg Plan
1220 ±100 / ±250 kN T&C ±0.04% ±0.04% 0.05 mm 4.0 mV/V 4.3 kg Plan
1221 0-125 / 0-250 kN Compression ± 0,05% ± 0,05% 0,05 mm 4,0 mV/V 3,1 kg Plan
1231 0-450 kN Compression ± 0,05% ± 0,05% 0,08 mm 4,0 mV/V 6 kg Plan
1232 ±450 kN T&C ±0.04% ±0.04% 0.080 mm 4.0 mV/V 11.8 kg Plan
1240 ±900 kN T&C ±0.06% ±0.06% 0.30 mm 4.0 mV/V 30.9 kg Plan
1241 0-900 kN Compression ± 0.05% ± 0.05% 0.10 mm 4.0 mV/V 18 kg Plan
1243 0-1350 / 0-1800 kN Compression ± 0,05% ± 0,05% 0,13 mm 4,0 mV/V 34 kg Plan
1244 ±1200 kN T&C ±0.08% ±0.08% 0.15 mm 4.0 mV/V 31.8 kg Plan
1252 ±1800 kN T&C ±0.09% ±0.09% 0.18 mm 4.0 mV/V 45 kg Plan
1260 ±2700 kN T&C ±0.10% ±0.10% 0.2 mm 4.0 mV/V 90 kg Plan
1280 ±4500 kN T&C ±0.15% ±0.15% 0.2 mm 4.0 mV/V 205 kg Plan
1290 ±9000 kN T&C ±0.20% ±0.20% 0.25 mm 4.0 mV/V 390 kg Plan

Installation

  • Bridge power supply: 1-20 VDC

  • Assembly 1: Traction only. Load applied via ball joint + nut. Sensor installation with baseplate, when the installation surface has imperfections (see accessories). Screw types, tightening torques here
  • Mounting 2: Compression only. The load is applied to the measuring surface. Sensor installation with baseplate, when the installation surface has imperfections (see accessories). Screw types, tightening torques here
  • Mounting 3: tension/compression. The load is applied via a threaded rod + nut. Sensor installed flush with the surface. Screw types, tightening torques here
  • Mounting 4: Compression only. The load is applied to the measuring surface. Sensor installed flush with surface. Screw types, tightening torques here
  • Mounting 5: Tension/compression, in-line, with baseplate and spherical plain bearings on either side of the transducer. Screw types, tightening torques here

Detailed installation instructions here

Signal conditioning and acquisition

Displays, Amplifiers and Data acquisition modules are offered wherever needed.

Refer also to selection below:

GSV-2TSDI 9870 PMI-520AJ GSV-1A GSV-6K GSV-8DS GSV-3USB
24-bit display with acquisition function High speed indicator High accuracy analog amplifier, Rail Din IP66 1-channel amplifier, Voltage or current output In-line miniature amplifier, voltage / current output High performance Data acquisition module system Data acquisition module with USB interface

Applications

  • Aerospace and automotive test benches
  • Materials testing
  • Test bench instrumentation
  • Hydraulic cylinder instrumentation
  • Sensor verification
  • Calibration benches

Options and accessories

Type
pancake
Precision (max error)
≤ 0.1 %
Nonlinearity (% FS)
± 0.04 %
Hysteresis
0.03 % FS
Nonrepeatability
0.01 % FS
Temperature Compensated Range
-10 to 45 °C
Température de fonctionnement
-55 to 90 °C
Zero Balance
0.0015 %PE/°C
Sensibilité du gain
0.0015 %/°C
Analog output signal
non-amplifié
Output Signal
2 , 4 mV/V
Résistance du pont
350 Ω
Tension d'alimentation
10 Vcc
Measurement direction
Traction & Compress.
Surcharge
150 %PE
Housing
Steel
Protection Class
IP40
Measuring Range (Force)
1 - 100 kN, 100 - 250 kN, > 250 kN, > 1 MN
Application
High Accuracy, OEM

Dimensions 1210, 1220, 1232

Dimensions 1240, 1244, 1252, 1260, 1280, 1290

Wiring

Options

Connectique

Connecteur Baïonnette Connecteur vissé Sortie câble 3m
Connecteur PT02E-10-6P / Option ACK ou CDS Connecteur PC04E-10-6P / Option AF ou ALD Option AJ

Pont de jauges redondant

double ou triple

TEDS

selon standard

Calibration

ISO 17025 ou E74 NIST

Base

1010 1010 1020 1032 1040 1044 1052 1060 1080 1090
B101(M) B102(M) B103(M) B112(M) B105(M) B116(M) B121(M) B122(M) B123(M) B125(M)

tige filetée de précision

rotules

Montage

Accessoire Descriptif
Ecrous ---

Acquisition

Accessoire Photo Descriptif
[Afficheur Visualisation la mesure en unité , gestion d'alarmes, affichage valeurs max-min
Conditionneur sortie ±5VDC, ± 10 Vcc, 0-10 Vcc ou 4-20 mA.
Systèmes d'acquisition Transmission des signaux de mesure vers un PC, un automate programmable, un enregistreur ou une application de supervision type SCADA. Post-traitement des données de mesure via Excel ou Matlab.

Related products

capteur de force précision

1100 Série - Haute précision

Capteur de force de précision 1.5 kN à 5kN
capteur de force de fatigue

1000 Série - Fatigue

Capteur de force de fatigue 1.25 kN à 25 kN
capteur de force bride

12x8 Série | Bride - Vérin

Capteur de force montage par bride 50 à 140 kN
GSV-1H - 1- channel straingauge amplifier in DIN rail housing

GSV-1H

1- channel straingauge amplifier in DIN rail housing
Phone +33 1 46 91 93 32 Contact Contact form Newsletter S'inscrire à la newsletter