Single-axis inertial inclinometer - 3 to 90° - low cost - analog output
- Single-axis inertial inclinometer
 - Measuring ranges: ± 3, ± 14.5, ± 30, ± 45, ± 60, or ± 90 °.
 - Accuracy: 0.02 to 0.05%.
 - Shock limit: 500g - Vibration: 20 grms
 - Bandwidth: 0-5 Hz
 - Output signal: ± 5 Vdc, 0-5 VDC or 4-20 mA
 - Operating temperature: -55 to +85°C
 - Power supply: 12Vdc to 28 Vdc
 - IP65 enclosure
 - Connection system: 4-pin terminal block or connector
 
Presentation
SMIC / SMIP series of precision single-axis inclinometers is designed for industrial applications requiring precision measurement on a limited budget. Extremely fine angle measurement is based on gravity measurement using a servo-controlled inertial table and an optical sensor. Accuracy is between 0.02% and 0.05% of full scale, depending on the measurement range, with a bandwidth of up to 5Hz and a resolution of 3.5µrad.
6 measurement ranges from ±3.0 to ±90.0° are available. The output signal is analog: ±5VDC, 0-5 VDC or 4-20 mA. Temperature sensitivity is extremely low: zero sensitivity is e.g. limited to 0.0015V/° over the ±90.0° range, temperature influence on slope is 100 ppm/°C.
The design of the SMIC / SMIP, whose sensitive elements are protected from shock and vibration by a dry damping system, enables precise, reliable measurement in harsh environments:
- operating temperature: -55 to +85°C
 - shock limit: 500g
 - IP65 waterproof steel case
 
Installation
The SMIC/SMIP inclinometer is mounted on the application using 2 M5 screws. Electrical connection is made either via a connector (SMIC) or a 4-pin terminal block (SMIP) mounted on the inclinometer. Optional connectors and cables are available.

Applications
- Radar / antenna control
 - Structural monitoring (bridges, buildings)
 - Acceleration control for automated trains and subways
 - Seismic monitoring
 - Production
 
- Technologie
 - Inertial
 - Number of Axis
 - 1 Axis
 - Etendue de mesure
 - 3 / 14.5 / 30 / 90 / 45 / 60 °
 - Résolution
 - 0.000001°- 0.001°
 - Bande passante (-3 dB)
 - 5 Hz
 - Application
 - High Accuracy
 - Nonlinearity (% FS)
 - ± 0.05 , 0.02 , 0.04 %
 - Sortie analogique
 - analog (Voltage)
 - Analog output signal
 - ± 5 VDC
 - Digital output signal
 - none
 - Tension d'alimentation
 - ± 15 Vcc
 - Température de fonctionnement
 - -55 to 85 °C
 - Connecteur
 - Bornier 4 pins ou Connecteur rond
 - Protection Class
 - IP65
 - Housing
 - Steel
 

Configuration options
- Measuring range
 - connector or terminal block
 - Special calibration
 
Available models
- SMIx-y-z
 - x: C: Connector, P: Terminal block
 - y: S: 0-5VDC, D: -/+ 5VDC, L: 4-20mA
 - z: measuring range
 
- Cable
 - Connector
 - Datalogger
 - Monitorint kit
 - Display