Single-axis inertial inclinometer - 3 to 90° - low cost - analog output
- Single-axis inertial inclinometer
- Measuring ranges: ± 3, ± 14.5, ± 30, ± 45, ± 60, or ± 90 °.
- Accuracy: 0.02 to 0.05%.
- Shock limit: 500g - Vibration: 20 grms
- Bandwidth: 0-5 Hz
- Output signal: ± 5 Vdc, 0-5 VDC or 4-20 mA
- Operating temperature: -55 to +85°C
- Power supply: 12Vdc to 28 Vdc
- IP65 enclosure
- Connection system: 4-pin terminal block or connector
Presentation
SMIC / SMIP series of precision single-axis inclinometers is designed for industrial applications requiring precision measurement on a limited budget. Extremely fine angle measurement is based on gravity measurement using a servo-controlled inertial table and an optical sensor. Accuracy is between 0.02% and 0.05% of full scale, depending on the measurement range, with a bandwidth of up to 5Hz and a resolution of 3.5µrad.
6 measurement ranges from ±3.0 to ±90.0° are available. The output signal is analog: ±5VDC, 0-5 VDC or 4-20 mA. Temperature sensitivity is extremely low: zero sensitivity is e.g. limited to 0.0015V/° over the ±90.0° range, temperature influence on slope is 100 ppm/°C.
The design of the SMIC / SMIP, whose sensitive elements are protected from shock and vibration by a dry damping system, enables precise, reliable measurement in harsh environments:
- operating temperature: -55 to +85°C
- shock limit: 500g
- IP65 waterproof steel case
Installation
The SMIC/SMIP inclinometer is mounted on the application using 2 M5 screws. Electrical connection is made either via a connector (SMIC) or a 4-pin terminal block (SMIP) mounted on the inclinometer. Optional connectors and cables are available.
Applications
- Radar / antenna control
- Structural monitoring (bridges, buildings)
- Acceleration control for automated trains and subways
- Seismic monitoring
- Production
- Technologie
- Inertial
- Number of Axis
- 1 Axis
- Etendue de mesure
- 3 / 14.5 / 30 / 90 / 45 / 60 °
- Résolution
- 0.000001°- 0.001°
- Bande passante (-3 dB)
- 5 Hz
- Application
- High Accuracy
- Nonlinearity (% FS)
- ± 0.05 , 0.02 , 0.04 %
- Sortie analogique
- analog (Voltage)
- Analog output signal
- ± 5 VDC
- Digital output signal
- none
- Tension d'alimentation
- ± 15 Vcc
- Température de fonctionnement
- -55 to 85 °C
- Connecteur
- Bornier 4 pins ou Connecteur rond
- Protection Class
- IP65
- Housing
- Steel
Configuration options
- Measuring range
- connector or terminal block
- Special calibration
Available models
- SMIx-y-z
- x: C: Connector, P: Terminal block
- y: S: 0-5VDC, D: -/+ 5VDC, L: 4-20mA
- z: measuring range
- Cable
- Connector
- Datalogger
- Monitorint kit
- Display