Ref: ECL 8439

Hydrostatic liquid level sensor - 10 mbar to 6 Bar

  • Measuring range: 10 cm to 60m water column / 10 mbar to 6 bar
  • Accuracy: ±0.30 %.
  • Output signal: 4-20 mA
  • Type of measurement: water level
  • Measuring principle: Thick film on ceramic
  • Electrical connection: Cable output
  • Construction: Sensor: Ceramic, Fitting and Housing: Stainless steel AISI316L or AISI318L
  • Waterproofing: IP68
  • Frequency response: 1 kHz depending on model
  • Temperature: -25 °C to +70 °C

Download the product sheet

?

Introduction

The ECL 8439 liquid level sensor is designed for vertical insertion into a tank or well for complete immersion in the fluid. The fully welded stainless steel sensor body and Al2O3 ceramic diaphragm are corrosion resistant to most fluids. The connection system consists of a waterproof cable.

The pressure ranges are from 10 mbar to 6 Bar (10 cm to 60m water column). The total accuracy is 0.30%. The output signal is a 4-20 mA.

Specifications

measuring ranges 0-0.1, 0-0.16, 0-0.2, 0-0.4, 0-0.5, 0-0.6, 0-1, 0-1.6, 0-2, 0-2.5, 0-4, 0-6
Sensor Ceramic A2lO3
Output signal 4-20 mA
Connectic Cable PUR ou PE

Setup

Configuration options include:

  • Extended operating temperature range.
  • Most amplified models have internal shunt calibration circuits as a standard feature to facilitate sensor configuration on the acquisition system.

Applications

  • oil and gas
  • pumps and compressors
  • marine
Type
Submersible
Measuring Range
< 1 bar, < 100 bar
Precision (max error)
0.5 %
Nonlinearity (% FS)
± 0.25 %
Température de fonctionnement
-18 to 63 °C
Sortie analogique
analog (Voltage), analog (Current)
Application
Sbmersible
Tension d'alimentation
10 Vcc
Protection Class
IP68

  • Extended operating temperature range
  • Electrical connection
  • Amplified output (5 Vdc or 10 Vdc and 4 mA to 20 mA)
  • Display
  • Hydraulic port adapter
  • Conditioner

Related products

Differential pressure sensor

FP2000 (FDW, FDD)

Liquid / Liquid (FDW) or Liquid / Gas (FDD) differential pressure sensor
Capteur de pression absolue

Model Z

Absolute pressure sensor - 35 mbar to 4000 bar - intrinsically safe
Water level sensor

LL-V

Vertical entry liquid level sensor. 50 mbar to 3,5 Bar
Capteur de niveau de remplissage avec flotteur

TFC

Filling level sensor with float