Ref: LIPS X112 / E112 / M112
Gauge Head Position Sensor - 0-50 mm - ATEX
- Type : Non-contact rod displacement sensor, stand alone
- ATEX versionof P112 sensor
- Designed for gauge head positioning
- Measuring range : 0-5 to 0-50 mm
- Non-linearity : 0.25% FS - 0.1% optional for ranges between 10 and 50 mm
- Bandwidth : 0-10 kHz
- Output signal : 0.5-4.5V dc ratiometric
- Spring loaded plunger with a dome end
- MTBF : 350,000 hrs at 40°C
- Axial output connector or cable
- Mounting : threaded rod or ball joint
- Operating temperature : -40°C to 80°C
- Construction : Stainless steel
- Protection : IP 67
- Diameter: 19 mm
- Use of Galvanic Isolation Amplifier mandatory
Log in to see the price
Login
?
Introduction
The LIPS X112 | E112 | M112 | G112 | H112 is a range of inductive linear displacement transducers designed for gauge head positioning in industrial and scientific applications. These are ATEX versions of the P112 transducer.
Positek ATEX sensors must be used with a galvanic barrier to meet intrinsic safety requirements. The X005 barrier is specially designed for Positek sensors, making it the ideal choice. Various configuration options are available for the output signal.
)
ATEX version / Intrinsic safety
- Model X112: Intrinsically safe for gases -> Ex II 1G
- Model E112 : Intrinsically safe for gas and dust -> Ex II 1GD
- Model M112: Intrinsically safe for mining -> Ex I/II M1/GD *
- Model G112: Intrinsically safe for gases -> Class I, Zone 0 Ex ia / AEx ia
- Model H112: Intrinsically safe for gas and dust -> Class I, Zone 0 Ex ia / AEx ia
Applications
- Gauge head positioning
- Technologie
- Linear inductive
- Etendue de mesure linéaire
- 5 / 50 mm
- Measuring range
- 0 à ±50 mm
- Nonlinearity (% FS)
- ± 0.25 %
- Bande passante (-3 dB)
- 10000 , 300 Hz
- Signal otuput
- 0-5 VDC
- Analog output signal
- 0-5 VDC
- Normes / Certifications
- ATEX
- Protection Class
- IP67
- Tension d'alimentation
- 10 Vcc
- Housing
- Steel
- Application
- High Accuracy, ATEX
Dimensions
Please refer to the technical data sheets for the various sensors
- Connection (connector or cable, position)
- Mounting
- Probe
- Range
- Linearity (standard or 0.1%)
- Galvanic Isolation Amplifier
Related products
HL-750 - ATEX
LVDT position sensor | ± 25 mm to ± 250 mm | ATEX
LIPS X103 / E103 / M103
Push rod displacement sensor - 0-5 to 0-50 mm - IP67
LIPS X111 | E111 | M111