Submersible linear displacement sensor 100m - 0 to 800mm
- Inductive linear displacement sensor
- ATEX version of the S114 sensor
- IP68 Immersible 10 bar (depth: 100m)
- Measuring range: 0-5 to 0-800 mm
- Linearity : 0,25% FS (range 0 to 450 mm) - 0,5% FS (range 450-800mm) - Option : 0,1% FS (only for ranges between 10 and 400 mm)
- Output signal: 0.5 - 4.5VDC ratiometric
- Construction: 316 stainless steel
- Mounting: Body: M5 ball joint or flange. Moving part: M5 ball or M5 thread. Probe option up to 300mm
- Connection: axial or radial cable outlet
- Bandwidth: 0-10 kHz
- Body diameter: 35mm
- MTBF : 350,000 hrs at 40°C
- Use of Galvanic Isolation Amplifier mandatory
Introduction
The LIPS X114 | E114 | M114 | G114 | H114 range of inductive linear displacement transducers is the ATEX version of the S114. It is therefore also the IP68 waterproof, 10 bar submersible and ATEX version of the P101 sensor. It is also derived from the X101 (with submersible specs). It measures displacements of up to 800mm at depths of up to 100 m, with accuracy better than 0.5%, 10kHz bandwidth and virtually infinite resolution. The measurement range is customizable between 0-5 mm and 0-800 mm in 1 mm increments. The output signal is perfectly linear with displacement.
Positek ATEX sensors must be used with a galvanic barrier to meet intrinsic safety requirements. The X005 barrier is specially designed for Positek sensors, making it the ideal choice. Various configuration options are available for the output signal.
ATEX version / Intrinsic safety
- Model X114: Intrinsically safe for gases -> Ex II 1G
- Model E114 : Intrinsically safe for gas and dust -> Ex II 1GD
- Model M114: Intrinsically safe for mining -> Ex I/II M1/GD *
- Model G114: Intrinsically safe for gases -> Class I, Zone 0 Ex ia / AEx ia
- Model H114: Intrinsically safe for gas and dust -> Class I, Zone 0 Ex ia / AEx ia
Applications
The LIPS X114 | E114 | M114 | G114 | H114 sensor is recommended for :
- Displacement measurements in seawater
- Vibration measurement
- Position control
- Position monitoring
- Actuators on construction equipment
- Valve instrumentation
- Technologie
- Linear inductive
- Etendue de mesure linéaire
- 800 mm
- Measuring range
- 0 à ±50 mm, ±51 à ±250 mm, ± 251 à ±2 m
- Nonlinearity (% FS)
- ± 0.25 %
- Bande passante (-3 dB)
- 10 Hz
- Signal otuput
- 0-5 VDC
- Analog output signal
- 0-5 VDC
- Normes / Certifications
- ATEX
- Température de fonctionnement
- -40 to 80 °C
- Protection Class
- IP68
- Housing
- Stainless Steel
- Application
- High Accuracy, ATEX, Sbmersible
Please refer to the technical data sheets for the various sensors
- Range customizable from 0 to 800mm
- Linearity
- Galvanic Isolation Amplifier