Inductive linear displacement transducer 0-800 mm - IP67 - Stand-alone mounting - ATEX option
- Type : Non-contact rod displacement transducer, stand alone, ATEX version of P101 sensor
- Measuring range : 0-5 to 0-800 mm
- Non-linearity : 0.25% (0.1% optional for ranges between 10 and 400 mm)
- Output : ratiometric 0.5-4.5V dc
- MTBF : 350,000 hrs at 40°C
- Axial output connector or cable
- Mounting : threaded rod or ball joint
- Operating temperature : -40°C to 80°C
- Construction : Stainless steel
- Protection : IP 65/67
- Diameter: 35mm
- Optional probe version
- Use of Galvanic Isolation Amplifier mandatory
Introduction
The LIPS X101 | E101 | M101 | G101 | H101 range is a precise and robust inductive linear displacement transducer that meets the needs of most scientific and industrial applications in hazardous areas (ATEX). Measurement ranges can be specified to the centimeter, from 0-5mm to 0-800mm. These are the ATEX versions of the P101 sensor.
The sensors are very compact and space-saving, and are supplied with an output calibrated to the required stroke, from 0-5mm to 0-800mm, and with full built-in EMC protection.
The non-contact, inductive technology features excellent durability (MTBF > 350,000 hours). Another advantage: infinite resolution, and excellent frequency response (> 10 kHz), for high-dynamic servo control or vibration studies.
Positek ATEX sensors must be used with a galvanic barrier to meet intrinsic safety requirements. The X005 barrier is specially designed for Positek sensors, making it the ideal choice. Various configuration options are available for the output signal.
The cable length between sensor and amplifier can be up to 1 km.
ATEX version / Intrinsic safety
- Model X101: Intrinsically safe for gases -> Ex II 1G
- Model E101 : Intrinsically safe for gas and dust -> Ex II 1GD
- Model M101: Intrinsically safe for mining -> Ex I/II M1/GD *
- Model G101: Intrinsically safe for gases -> Class I, Zone 0 Ex ia / AEx ia
- Model H101: Intrinsically safe for gas and dust -> Class I, Zone 0 Ex ia / AEx ia
Applications
- Linear displacement measurements
- Vibration measurement
- Displacement and control servoing
- Position monitoring
- Actuators on construction machinery
- Laboratory measurements
- Technologie
- Linear inductive
- Etendue de mesure linéaire
- 800 mm
- Measuring range
- 0 à ±50 mm, ±51 à ±250 mm, ± 251 à ±2 m
- Nonrepeatability
- 0.01 % FS
- Nonlinearity (% FS)
- ± 0.25 %
- Bande passante (-3 dB)
- 10000 Hz
- Signal otuput
- 0-5 VDC, 0-10VDC, ± 5 VDC, ± 10 VDC, 4-20 mA
- Analog output signal
- 0-5 VDC
- Normes / Certifications
- ATEX
- Température de fonctionnement
- -40 to 125 °C
- Protection Class
- IP65, IP67
- Tension d'alimentation
- 10 Vcc
- Housing
- Steel
- Cable
- Connector or cable
- Application
- ATEX
Dimensions
Please refer to the technical data sheets for the various sensors
- Connection (connector or cable, position)
- Mounting
- Probe
- Range
- Linearity (standard or 0.1%)
- Galvanic Isolation Amplifier