1-channel eddy current displacement sensor - 0.5 to 60 mm - 50 kHz - Analogue output
- Non-contact eddy current measurement system
- Including: sensor + cable + electronics
- Measuring range: 0.5 mm to 60 mm
- Bandwidth: 0 to 50 kHz
- Resolution: 0.1 to 6µm depending on the measuring range
- Voltage output: 0-10 VDC, +/- 5 VDC, 4-20mA
- Power supply: 15-30 VDC
- IP67 sensor, insensitive to oil, dust, humidity, magnetic fields
- Electronics: IP40, DIN rail mounting
- Operating temperature (sensor + cable): standard: -67 to 221°F, cryogenic version: -320.8°C to 401°C
- RoHS and CE
Non-contact displacement/position sensor
Principle of operation
The eddy current sensor KD-2306 measures displacements, positions or distances, without contact, between the sensor head and a magnetic or non-magnetic metal part, over measuring ranges from 0.5 to 60 mm. The measurement is characterised by an excellent resolution (down to 0.1µm), a very high frequency response (50 kHz) and is insensitive to the environment (wet, electro-magnetic, cryogenic, cutting oil, etc.). The analogue output signal (DC voltage or 4-20mA) is compatible with any analogue input from a PC, PLC or data acquisition system.
Calibration / adjustment
Calibration of the KD-2306 is performed at the factory, with the probe and the metal target of the application, under the measurement conditions (temperature, supply voltage, etc.). Optionally, calibration points can be specified to optimise accuracy. When installing the system, or when using a new metal target, the gain and offset of the amplifier can be adjusted to optimise the linearity of the response. Shims and micrometers for this purpose are optional.
More information on the principle of Eddy Current measurement: here
OEM version
An OEM version of the KD-2306 is available for integration into machine tools and test benches. The sensors are identical. The electronics are in the form of a printed circuit board (PCB) for direct integration into the application to be equipped. See Documentation
Setup
The KD-2306 system consists of a probe with integrated cable (29 models available) and DIN rail mounted conditioning electronics.
Version standard: [-67/221°]
Sensor | 2UM | 2U | 1S | 1SM | 1U1 | 1SU | 5U | 2S1 | 2UB1 | 2S | 3U1 |
---|---|---|---|---|---|---|---|---|---|---|---|
Range | 0.5 | 0.5 | 1.0 | 1.0 | 1.0 | 1.3 | 1.3 | 2.0 | 2.0 | 2.5 | 3.0 |
Magnetic/non-magnetic target | -/x | x/- | x/- | -/x | x/- | x/- | x/- | x/x | x/x | x/x | x/- |
Static resolution [µm] | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 | 0.2 | 0.3 | |||
Shielded (O/N) | - | - | x | x | - | - | - | - | x | - | - |
Cable length [m] | 2 | 2 | 3 | 3 | 3 | 3 | 2 | 3 | 3 | 3 | 3 |
Sensor | 4S1 | 4SB | 6U1 | 6C | 8C | 15U1 | 10CU | 30U1 | 12CU | 60U1 |
---|---|---|---|---|---|---|---|---|---|---|
Range | 4.0 | 4.0 | 6.0 | 6.4 | 12.7 | 15.0 | 24.4 | 30.0 | 50.8 | 60.0 |
Magnetic/non-magnetic target | O/O | O/O | x/x | O/O | x/x | O/O | O/O | O/O | O/O | O/O |
Static resolution [µm] | 0.4 | 0.4 | 0.6 | 0.6 | 1.3 | 1.5 | 2.5 | 3.0 | 5.0 | 6.0 |
Shielded (O/N) | x | x | - | x | x | - | - | - | - | - |
Cable length [m] | 3 | 3 | 3 | 4,5 | 4,5 | 3 | 4,5 | 3 | 4,5 | 2 |
Cryogenic versions: [-320.8/399.2°]
Sensor | 1UEP | 1SUM | 9U | 12U | 16U | 26U | 38U | 51U |
---|---|---|---|---|---|---|---|---|
Range | 1.0 | 1.3 | 4.0 | 5.0 | 8.0 | 12.0 | 20.0 | 25.0 |
Magnetic/non-magnetic target | -/x | -/x | x/- | x/x | x/x | x/x | x/x | x/x |
Static resolution [µm] | 0.1 | 0.1 | ||||||
Shielded (O/N) | - | - | - | - | - | - | - | - |
Cable length [m] | 3 | 3 | 2 | 2 | 2 | 2 | 2 | 2 |
- Non-magn: non-magnetic target type aluminium, stainless steel
- Magn: magnetic target type steel 4130
Dimensions
Other probes are available on request. Please contact us.
KD-2306 applications
- Turbine or compressor speed measurement
- Detection of shaft deformation (runout)
- Shaft misalignment detection
- Displacement or position measurement
- Vibration measurement
- Quality control
- Machining inspection
- Thickness measurement
- Orbit measurement
- Technologie
- Eddy Current
- Etendue de mesure linéaire
- 0.5 / 60 mm
- Measuring range
- 0 à ±50 mm, ±51 à ±250 mm
- Nonrepeatability
- 0.1 % FS
- Nonlinearity (% FS)
- ± 0.1 %
- Bande passante (-3 dB)
- 50000 Hz
- Analog output signal
- 0-10 VDC
- Protection Class
- IP40, IP67
- Tension d'alimentation
- 10 Vcc
- Housing
- Steel
- Fiche-produit-KD_2306-FR.pdf
- Datasheet_KD_23_06_PMI_EN.pdf
- Manuel utilisateur KD 2306
- Specifications des sondes
- Manuel-Calibration-Kaman-2021.pdf
- Kaman_1S_sensor_STEP.zip
- Kaman_1SM_sensor_STEP.zip
- Kaman_1SU_sensor_STEP.zip
- Kaman_1SUM_sensor_STEP.zip
- Kaman_1U1_sensor_STEP.zip
- Kaman_1UEP_sensor_STEP.zip
- Kaman_2S_sensor_STEP.zip
- Kaman_2S1_sensor_STEP.zip
- Kaman_2SMT_sensor_STEP.zip
- Kaman_2UB1_sensor_STEP.zip
- Kaman_3U1_sensor_STEP.zip
- Kaman_4S1_sensor_STEP.zip
- Kaman_4SB_sensor_STEP.zip
- Kaman_6C_sensor_STEP.zip
- Kaman_8C_sensor_STEP.zip
- Kaman_6U1_sensor_STEP.zip
- Kaman_9U_sensor_STEP.zip
- Kaman_10C_sensor_STEP.zip
- Kaman_10CU_sensor_STEP.zip
- Kaman_12U_sensor_STEP.zip
- Kaman_15U1_sensor_STEP.zip
- Kaman_16U_sensor_STEP.zip
- Kaman_26U_sensor_STEP.zip
- Kaman_30U1_sensor_STEP.zip
- Kaman_38U_sensor_STEP.zip
- Kaman_51U_sensor_STEP.zip
- Kaman_60U1_sensor_STEP.zip
Sensors
- Special calibration with non-standard measuring range
- Temperature compensation of the sensors
- Special cable; connector on the cable, watertight feedthrough
- Sensor treatment against moisture
- Adaptation to special target geometry
- Sensor cable length
- Calibration micrometer
- Teflon thickness gauge
- 12 or 24Vdc power supply
- Product training and calibration techniques
- Data acquisition