Hardened inductive probe - 0-5 to 0-50 mm - IP67 - Diameter : 19 mm - ATEX option
- Type : Inductive probe
 - Measuring range : 0-5 to 0-50 mm
 - Non-linearity : 0.25% (0.1% optional)
 - Bandwidth : 0-10 kHz
 - Analogue voltage output
 - MTBF : 350,000 hrs at 104°F
 - Axial output connector or cable
 - Mounting : threaded rod
 - Operating temperature: -40°F to 257°F
 - Construction: Stainless steel
 - Protection : IP 67
 - Diameter : 19 mm
 - ATEX version (if Ex II 1G and Ex ia IIC T4 Ga optional)
 
Introduction
The LIPS P112 inductive probe allows precise measurement of position or displacement over ranges from 0-5mm to 0-50mm. Incorporating inductive technology, the P112 is designed for the harshest environments: operating temperature: -40 to +257°F, IP67, excellent durability (MTBF > 350,000 hours), vibration resistance of 10g.
The analogue output signal is proportional to the absolute position (non-linearity: < ± 0.25mm for 100mm displacement, optionally reduced to ± 0.1mm). The resolution is infinite, the frequency response very high (> 10 kHz).

Installation
The sensor body is made of stainless steel, with a diameter of only 19mm. The fixed part (body) of the sensor P112 is fixed via a thread. The moving part, corresponding to the displacement measurement, is actuated by the spring in the sensor body. Clamps are also available.

The electrical connection is either a connector or a cable, in axial or radial position. Two potentiometers allow fine adjustment of zero and gain. The transducer is powered by DC voltage, and incorporates conditioning electronics for a voltage type output signal :
| Output | Power supply | 
|---|---|
| 0.5V to 4.5V DC ratiometric (default) | +5V DC nom. ±0.5V | 
| 0.5V-4.5V DC | +9-28V DC nom. 24V | 
| 0.5-9.5V DC | +13-28V DC nom 24V | 
ATEX version / Intrinsic safety
The LIPS X112 is the ATEX version of the P112. The LIPS X112 is certified Intrinsically safe Ex II 1G and Ex ia IIC T4 Ga (Ta= -40°C to 80°C) . The measurement performance and size are identical. The X112 must be used with an ATEX galvanic barrier, like the X005. The output signal is analogue, type 0.5 - 9.5V or 4-20 mA See LIPS X112 data sheet.
Applications
- Linear displacement measurements
 - Vibration measurement
 - Displacement and control servoing
 - Position monitoring
 - Actuators on construction machinery
 
- Technologie
 - Linear inductive
 - Etendue de mesure linéaire
 - 5 / 50 mm
 - Measuring range
 - 0 à ±50 mm
 - Nonlinearity (% FS)
 - ± 0.25 %
 - Bande passante (-3 dB)
 - 10000 , 300 Hz
 - Signal otuput
 - 0-5 VDC, 0-10VDC
 - Analog output signal
 - 0-10 VDC
 - Normes / Certifications
 - ATEX
 - Protection Class
 - IP67
 - Tension d'alimentation
 - 10 Vcc
 - Housing
 - Steel
 - Application
 - Taster
 
Dimensions

| CONNECTOR/CABLE OPTIONS | 
|---|
| Connector - Hirschmann ELWIKA 4102 Axial, IP67 | 
| Connector - Hirschmann ELWIKA 4102 Radial, IP67 | 
| Cable with Pg 9 gland Axial, IP67 | 
| Cable with boot. Radial, IP67 | 
| Cable length – please specify length in cm (50 cm by default) | 
- Cable extension
 - Connector
 - Sensor power supply
 - Signal conditioner
 - Display
 - Data acquisition