Hardened inductive probe - 0-5 to 0-50 mm - IP67 - Diameter : 19 mm - ATEX option
- Type : Inductive probe
- Measuring range : 0-5 to 0-50 mm
- Non-linearity : 0.25% (0.1% optional)
- Bandwidth : 0-10 kHz
- Analogue voltage output
- MTBF : 350,000 hrs at 104°F
- Axial output connector or cable
- Mounting : threaded rod
- Operating temperature: -40°F to 257°F
- Construction: Stainless steel
- Protection : IP 67
- Diameter : 19 mm
- ATEX version (if Ex II 1G and Ex ia IIC T4 Ga optional)
Download the product datasheet
Introduction
The LIPS P112 inductive probe allows precise measurement of position or displacement over ranges from 0-5mm to 0-50mm. Incorporating inductive technology, the P112 is designed for the harshest environments: operating temperature: -40 to +257°F, IP67, excellent durability (MTBF > 350,000 hours), vibration resistance of 10g.
The analogue output signal is proportional to the absolute position (non-linearity: < ± 0.25mm for 100mm displacement, optionally reduced to ± 0.1mm). The resolution is infinite, the frequency response very high (> 10 kHz).

Installation
The sensor body is made of stainless steel, with a diameter of only 19mm. The fixed part (body) of the sensor P112 is fixed via a thread. The moving part, corresponding to the displacement measurement, is actuated by the spring in the sensor body. Clamps are also available.

The electrical connection is either a connector or a cable, in axial or radial position. Two potentiometers allow fine adjustment of zero and gain. The transducer is powered by DC voltage, and incorporates conditioning electronics for a voltage type output signal :
| Output | Power supply |
|---|---|
| 0.5V to 4.5V DC ratiometric (default) | +5V DC nom. ±0.5V |
| 0.5V-4.5V DC | +9-28V DC nom. 24V |
| 0.5-9.5V DC | +13-28V DC nom 24V |
ATEX version / Intrinsic safety
The LIPS X112 is the ATEX version of the P112. The LIPS X112 is certified Intrinsically safe Ex II 1G and Ex ia IIC T4 Ga (Ta= -40°C to 80°C) . The measurement performance and size are identical. The X112 must be used with an ATEX galvanic barrier, like the X005. The output signal is analogue, type 0.5 - 9.5V or 4-20 mA See LIPS X112 data sheet.
Applications
- Linear displacement measurements
- Vibration measurement
- Displacement and control servoing
- Position monitoring
- Actuators on construction machinery
- Technologie
- Linear inductive
- Etendue de mesure linéaire
- 5 / 50 mm
- Measuring range
- 0 à ±50 mm
- Nonlinearity (% FS)
- ± 0.25 %
- Bandwidth (+/-5%)
- 10000 , 300 Hz
- Signal otuput
- 0-5 VDC, 0-10VDC
- Analog output signal
- 0-10 VDC
- Normes / Certifications
- ATEX
- Protection Class
- IP67
- Atex
- No
- Tension d'alimentation
- 10 Vcc
- Housing
- Steel
- Application
- geotechnical, Taster
Dimensions

| CONNECTOR/CABLE OPTIONS |
|---|
| Connector - Hirschmann ELWIKA 4102 Axial, IP67 |
| Connector - Hirschmann ELWIKA 4102 Radial, IP67 |
| Cable with Pg 9 gland Axial, IP67 |
| Cable with boot. Radial, IP67 |
| Cable length – please specify length in cm (50 cm by default) |
- Cable extension
- Connector
- Sensor power supply
- Signal conditioner
- Display
- Data acquisition