High-precision geophysical tiltmeter ±0.046° to ±8° - Analog or digital
- high-precision biaxial inclination measurement Measurement ranges: ±0.046°, ±0.46°, ±0.5°, ±5°, ±0.8°, ±8° * Resolution: 0 µrad or 1 µrad
- Resolution: 0.1 µrad or 1 µrad
- Electrolytic technology
- Low-pass filter - 0.1 Hz
- Version A701-2A / D701-A: high-sensitivity version (0.1 or 1 μradian/mV )
- Version A701-2B / D701-B: medium range version (0.1 or 1°/V)
- Voltage output (A701) or RS-232/485 (D701)
- Temperature output
- Operating temperature: -40 to +85°C
- Power supply: ±11 to ±15 VDC (A701) or 7-28 VDC (D701)
- Dimensions: 15 x 15 x 10 cm
- Cable length 3m included
- IP65 version optional
Overview
The 701-2 series of inclinometers are tilt measurement platforms for geophysical applications, combining high accuracy and stability. The 701-2 system is built on two high-precision electrolytic sensing elements mounted perpendicularly, enabling detection of minute movements on the X and Y axes. Resolution ranges from 0.1 to 2 µrad, depending on the measurement range.
5 measurement ranges are available: ±0.046°, ±0.5°, ±0.8°, ±4° and ±8°. The analog versions (A701-2A and A701-2B) includes 2 switches for selecting the gain and filter constant from 2 values, allowing measurement over the ranges ±0.46°, ±8°. Sensitivity is inversely proportional, for analog (±8 VDC (unipolar) or ±16 VDC (differential)) or digital (RS-232/485 for the D701-2) output signals. The A701-2-4X model is waterproof to IP65, for use in dusty and/or damp environments.
Specifications
Model | A701-2A-HG | A701-2A-LG | A701-2B-HG | A701-2B-LG | A701-2A(4X) | A701-2B(4X) |
---|---|---|---|---|---|---|
Number of axes | X, Y | X, Y | X, Y | X, Y | X, Y | X, Y |
measurement range | ±800 μradians (±0.046°) | ±8000 μradians (±0.46°) | ± 0.8° | ± 8° | ±8000 μradians (±0.46°) | ± 4° |
Sensitivity | 0.1µrad/mv | 1µrad/mv | 0.1°/v | 1°/V | 1 µrad/mv | 0.5°/V |
Resolution | 0.1 µrad | 0.1 µrad | 1 µrad | 1 µrad | 2 µrad | 2 µrad |
Non-linearity | 0.2% | 2% | 0.2% | 1.5% | 1% | 2% |
Signal output | ±8VDC (uni.); ±16VDC (diff) | ±8VDC (uni.); ±16VDC (diff) | ±8VDC (uni.); ±16VDC (diff) | ±8VDC (uni.); ±16VDC (diff) | ±8VDC (uni.); ±16VDC (diff) | ±8VDC (uni.); ±16VDC (diff) |
Zero temperature sensitivity | ±3 μradians/°C (typical) | ±3 μradians/°C (typical) | ±0.001°/°C (typical) | ±0.001°/°C (typical) | ±4 μradians/°C (typical) | ±4 μradians/°C (typical) |
Gain temperature sensitivity | 0.05%/°C (typical) | 0.05%/°C (typical) | 0.05%/°C (typical) | 0.04%/°C (typical) | 0.04%/°C (typical) | 0.05%/°C (typical) |
Temperature output | 0.1°C/mV | 0.1°C/mV | 0.1°C/mV | 0.1°C/mV | 0.1°C/mV | 0.1°C/mV |
IP Grade | IP65 | IP65 |
Installation
The platform is placed on the reference surface. Leveling and calibration are performed using feet fitted with invar adjustment screws. 3m cable included. Permissible supply voltage for analog model is 11-15VDC (A701-2) or 7-28VDC (D701).
Applications
- antenna leveliing
- tide measurement
- volcano monitoring
- telescope orientation
- high-precision metrology
- precision mechanical production
- Technologie
- Geotechnical
- Number of Axis
- 2 Axis
- Etendue de mesure
- 0.46 / 8 °
- Résolution
- 0.000001°- 0.001°
- Bande passante (-3 dB)
- 5 , 0.5 Hz
- Application
- High Accuracy, geotechnical
- Nonlinearity (% FS)
- ± 2 %
- Sensibilité du gain
- 0.02 %/°C
- Sortie analogique
- analog (Voltage)
- Analog output signal
- ±8 VDC
- Digital output signal
- RS-485, RS-232
- Tension d'alimentation
- ±11 to ±15 VDC
- Température de fonctionnement
- -8 to 70 °C
- Protection Class
- IP60, IP65
- Housing
- Aluminium
- Installation
- Platform
Configuration
- Special calibration
- Connectivity (cable length, connector)
- Measurement range
- Output type (voltage or digital)
- Cable
- Data acquisition
- Display