Inductive probe - 0-2 to 0-50 mm - IP67 - ⌀ 19 - ATEX option
- Type: Inductive probe - ATEX version of P118 sensor
- Measuring range: 0-5 to 0-50 mm
- Diameter: 19 mm
- Non-linearity: 0.25% (0.1% optional for ranges superior to 10 mm)
- Bandwidth: 0-10 kHz
- Output : 0.5-4.5V dc ratiometric
- MTBF: 350,000 hrs at 40°C
- Axial output connector or cable
- Mounting: flange
- Operating temperature: -40°F to 80°C
- Construction: Stainless steel IP 67
- Use of Galvanic Isolation Amplifier mandatory
Introduction
The LIPS X118 | E118 | M118 | G118 | H118 range of inductive probes enables precise measurement of position or displacement over ranges from 0-5mm to 0-50mm. It is the ATEX version of the P118 sensor. Incorporating inductive technology, the sensor is designed for the harshest environments: operating temperature: -40 to +80°C, IP67, excellent durability (MTBF > 350,000 hours), 10g vibration resistance.
Positek ATEX sensors must be used with a galvanic barrier to meet intrinsic safety requirements. The X005 barrier is specially designed for Positek sensors, making it the ideal choice. Various configuration options are available for the output signal.
ATEX version / Intrinsic safety
- Model X118: Intrinsically safe for gases -> Ex II 1G
- Model E118 : Intrinsically safe for gas and dust -> Ex II 1GD
- Model M118: Intrinsically safe for mining -> Ex I/II M1/GD *
- Model G118: Intrinsically safe for gases -> Class I, Zone 0 Ex ia / AEx ia
- Model H118: Intrinsically safe for gas and dust -> Class I, Zone 0 Ex ia / AEx ia
Applications
- Linear displacement measurements
- Vibration measurement
- Displacement and control servoing
- Position monitoring
- Actuators on construction machinery
- Technologie
- Linear inductive
- Etendue de mesure linéaire
- 50 mm
- Measuring range
- 0 à ±50 mm
- Nonlinearity (% FS)
- ± 0.25 %
- Bande passante (-3 dB)
- 10000 Hz
- Signal otuput
- 0-5 VDC
- Analog output signal
- 0-5 VDC
- Normes / Certifications
- ATEX
- Température de fonctionnement
- -40 to 125 °C
- Protection Class
- IP67
- Tension d'alimentation
- 5 Vcc
- Housing
- Steel
- Application
- ATEX, Taster
Dimensions
Please refer to the technical data sheets for the various sensors
- Range customizable from 0 to 50 mm
- Linearity (standard or 0,1%)
- Galvanic Isolation Amplifier