Wire rope position transducer - IP40 - 50 mm to 2 m - TTL or analog output
- Cable displacement sensor
- Robust and economical
- Measuring ranges : 0-50mm to 0-2m
- Output signal : 0-10V, 0-5V, 4-20mA, TTL, ratiometric
- Non-linearity : 0.10 to 0.25% PE
- Repeatability : 0.015% of the measuring range
- Resolution : infinite
- Zero and gain adjustable on some models
- Optional cable speed output
- Construction : IP40 aluminum
Introduction
The STANDARD series of cable displacement transducers (PA, PB, P420, P510, EP, V, VP) is a rugged and cost-effective solution for measuring linear position and/or linear velocity in a clean, dry industrial environment. The aluminum sensor body is IP40.
The STANDARD series includes 13 measuring ranges from 50 mm to 2 m, and 7 types of analog (ratiometric, bridge circuit, 4-20 mA, 0 to 5 or 0 to 10 VDC, ± 10 VDC, ± 5 VDC) or digital (TTL quadrature) output signals. Gain and offset are adjustable on some models. Some models also provide a linear velocity measurement.
Specification
PA | PB | P420 | HX-P510 | EP | V | VP | |
---|---|---|---|---|---|---|---|
Measuring Range | 50 mm à 2 m | 50 mm à 2 m | 50 mm à 2 m | 50 mm à 2 m | 250 mm à 2 m | - | 50 mm à 2 m |
Technology | Potentiomètre | Potentiomètre | Potentiomètre | Potentiomètre | Codeur angulaire | - | Potentiomètre |
Resolution | infinie | infinie | infinie | infinie | 20 à 300µm | - | infinie |
non-linearity | 0,25% | 0,25% | 0,30% | 0,30% | 0,03% | - | 0,25% |
Voltage supply | 1 - 30 VDC | 1 - 30 VDC | 9 to 35 VDC | 9 to 35 VDC | +5 VDC ±5% or 8-28 VDC | - | 1 - 30 VDC |
Output signal | 92-98% de la tension d'alimentation | 0-18% de la tension d'alimentation | 4-20 mA | 0-5, +/-5, 0-10, +/- 10 VDC | 2 créneaux TTL en quadrature | - | 92-98% de la tension d'alimentation |
Operating temperature | -40° C à 95° C | -40° C à 95° C | -40° C à 95° C | -40° C à 95° C | -40° C à 95° C | - | -40° C à 95° C |
Bandwidth | TBD | TBD | TBD | TBD | TBD | - | TBD |
Span / zero réglables | NON | OUI | OUI | OUI | OUI | - | NON |
Speed signal | NON | NON | NON | NON | NON | OUI | NON |
Speed output signal | - | - | - | - | - | 0-10 VDC | 0-10 VDC |
Setup
The cable is directly or indirectly linked to the displacement to be measured, which allows a non-normal or non-linear displacement. The measurement can be offset by cable extensions. The sensor body and the cable are fixed on the fixed or mobile part of the measurement. The connector of the STANDARD is made of intertwined cables and protected by a reinforced urethane layer.
Applications
The STANDARD sensors are recommended for :
- static product applications
- Static laboratory testing
- Civil engineering and building
- Position monitoring
- Sample collection
Related products