Press Force Sensor | 0-2 to 0-100 kN
- Press force sensor
- 6 measurement ranges between 0-2 kN and 0-100 kN
- Bore diameter: 33 to 70 mm
- Accuracy: ±0.5% FS
- Operating temperature: -40 to 70 °C
- Maximum overload: 200%
- Signal output: 1 mV / V
- Construction: Stainless steel / Aluminum IP60
- Electrical connection : 3m cable
Overview
The PFLC force sensor is used for measuring compression force, such as that applied by a press. It has an accuracy of +/- 0.5% of full scale and is available in 6 measurement ranges from 0-2 kN to 0-100 kN. The stainless steel construction, rated IP 60, offers 200% overload protection and an operating temperature range from -10 to 70°C.
Specifications
Installation
The load washer is installed under the bolt head to measure the stress related to tightening. There are 8 threaded holes (M5 x 8, 45°) to enable secure attachment to the support and prevent rotation during tightening. With an overload tolerance of 150% of the measurement range, it ensures the sensor operates correctly during assembly and deflection phases.
Dimensions
Signal Conditioning and Acquisition
The PFLC S-type sensor operates with a supply of 2.5 to 10 Vdc. A complete and configured measurement chain is available by adding a display, conditioner, or acquisition module:
Portable Display | Desktop Display | Built-in Display | Analog Conditioner | Analog Conditioner | Analog Conditioner | Acquisition Module |
---|---|---|---|---|---|---|
9325 | GSV-2TSDI | MICRA-M | PMI-520AJ | GSV-1A | GSV-6K | GSV-3USB |
High-performance pocket display | 24-bit display with acquisition function | Basic display | Precision analog conditioner with voltage or current output | Analog conditioner IP66 with +/-10V or 4-20mA or 12±8mA output | Analog conditioner IP66 with +/-10V or 4-20mA or 12±8mA output | USB acquisition module with PC acquisition software |
Applications
- Hydraulic press verification
- Press-fit force control
- Contact force measurement
- Clamping force measurement
- Type
- Press Load
- Measuring Range
- 2000 , 5000 , 10000 , 20000 , 50000 , 100000
- Precision (max error)
- 0.5 %
- Nonlinearity (% FS)
- ± 0.25 %
- Hysteresis
- 0.25 % FS
- Nonrepeatability
- 0.1 % FS
- Temperature Compensated Range
- -15 to 70 °C
- Température de fonctionnement
- -40 to 70 °C
- Zero Balance
- 0.02 %PE/°C
- Sensibilité du gain
- 0.02 %/°C
- Output Signal
- 1 mV/V
- Résistance du pont
- 700 Ω
- Tension d'alimentation
- 5 Vcc
- Measurement direction
- Compression
- Surcharge
- 150 %PE
- Housing
- Steel
- Protection Class
- IP60
- Measuring Range (Force)
- 1 - 100 kN, 100 - 250 kN
- Measurement range
- Operating temperature
- Connectivity
- ISO-17025 calibration
- Amplifier
- Data Acquisition module
- Cabling