Stainless steel IP67 low-cost load pin 0-5 to 0-200kN
- Instrumented load pin for load measurement
- Standard measurement ranges: ±5kN, ±10kN, ±20kN, ±50kN, ±100kN, ±200kN
- Non-linearity: 0.5% of full scale
- Output signal: 1 mV/V (or amplified as an option)
- Dimensions: application-specific
- Overload protection: 150%
- Construction: stainless steel IP67
- Operating temperature: -20 to 70°C
- Connectivity: 3 m 4-wire cable or connector
- Options: Integrated amplifier, wireless, other dimensions, other measurement ranges, IP68...
Download the product datasheet
Overview
The ALP instrumented pin is installed in place of the original pin for load measurement/monitoring up to 20 tonnes, with a measurement accuracy of approximately 0.5 to 1% of full scale. The output signal is 1.0 mV/V excitation (5 or 10V). Overload protection is 150% of the measurement range.
Specifications

Installation
The pin is mounted in place of the standard pin in the clevis head and measures tensile and compressive forces applied to the cylinder surface. It is supplied with a 3 m cable and is suitable for outdoor use, with a stainless steel IP67 body and an operating temperature range of -20 to +70°C. The output signal (1.0 mV/V) can be amplified as an option.
Dimensions

Configuration options
-
Dimensions
-
Measurement ranges
-
Connectivity
-
Submersible version
-
Conditioning, acquisition: Display, Conditioner or acquisition modules
Applications
- Machine tool instrumentation
- Marine
- Lifting
- Weighing
- Measuring Range
- 5kN , 10kN , 20kN , 50kN , 100kN , 200kN
- Precision (max error)
- 1 %
- Nonlinearity (% FS)
- ± 0.5 %
- Hysteresis
- 0.25 % FS
- Nonrepeatability
- 0.1 % FS
- Temperature Compensated Range
- -20 to 70 °C
- Zero Balance
- 0.02 %PE/°C
- Sensibilité du gain
- 0.02 %/°C
- Analog output signal
- non-amplifié
- Output Signal
- 1 mV/V
- Résistance du pont
- 350 Ω
- Tension d'alimentation
- 5 Vcc
- Surcharge
- 150 %PE
- Housing
- Stainless Steel
- Protection Class
- IP67
- Poids
- 0.319
- Measuring Range (Force)
- 100 - 250 kN
- Application
- OEM, low cost
Dimensions

Connectivity

- Calibration in tension and/or compression
- Cable length
- Specific connector
- Extended temperature compensation
- ISO 17025 calibration
- Amplification (5VDC, 10VDC, 4-20mA)
- Submersible version
- TEDS
-
Single-channel conditioner: GSV-6K (inline), GSV-1H (DIN rail), GSV-1M (IP67) or GSV-6L (miniature)
-
Single-channel display: TRA-240 (basic) or GSV-2MSDI (with standalone logger function)
-
Desktop conditioner/display GSV-2TSDI
-
Four-channel conditioner GSV-1A4
-
Single-channel: GSV-2AS (RS-232/485 or CANopen) or GSV-3USB (1 or 2 channels USB)
-
Four-channel GSV-4USB (USB)
-
Six-channel GSV-6BT (Bluetooth) or GSV-6LTE (LTE datalogger)
-
Eight-channel GSV-8DS (LAN/WiFi/USB/EtherCAT/CANRS-232)