High-precision force sensor | ±1.5 kN to ±900 kN | Accuracy ± 0.02 %
- High-precision force sensor
- Accuracy: 0.02% to 0.08% depending on version
- Measurement range: ±1.5 kN to ±900 kN in tension/compression, 0-5 to 0-250 kN in compression only
- Calibration in tension/compression or compression only (certificate provided)
- Mechanical compensation for transverse forces
- Very low deflection (0.05 to 0.20 mm depending on model)
- Output signal: 2 or 4 mV/V
- Temperature sensitivity < 0.0015% / °C
- Overload protection: 150% of full scale
- Operating temperature: -55 to 90°C
- ISO-376 versions available as option
- Double or triple bridge options
- Connector or cable output
- Weight: from 1.5 to 66 kg
- See the range of flat pancake-type force cells
Download the product datasheet
Overview
Very high-precision force sensor
The force sensors in the 1100 series are, after reference sensors, the most precise in the range. With accuracies between 0.02% and 0.08% of full scale depending on the model, these sensors provide remarkable absolute precision, including at low and intermediate loads. They are thus particularly suited for calibration benches, force verification benches, and all test benches operating across the full force range. Measurement ranges span from ±1.5 kN to ±900 kN.
Design
The design of the 1100 series sensors is the result of 50 years of continuous improvement. High precision is achieved through rigorous strain gauge pairing with the sensing element, as well as expertise in manufacturing and calibration. The construction also features very high repeatability (< 0.01%) and long-term stability (static accuracy: 0.02% to 0.06%). The design is furthermore nearly insensitive to eccentric forces (< 0.05% / cm) and transverse forces (< 0.1%), and highly robust, with overload protection of 150%.

The operating temperature range is -55 to 90°C. Calibration is temperature-compensated between -10 and 45°C.
Specifications
- Measurement: tension/compression (11x0) or compression only (11x1)
- Bridge supply: 1-20 VDC
- Bridge resistance: 350 Ohm
- Overload protection: 150%
| Model | Ranges | Measurement | Non-linearity | Hysteresis | Deflection | Output | Weight | Drawing |
|---|---|---|---|---|---|---|---|---|
| 1110 | ±1.5 / ±2.5 / ±5 / ±10 kN | T&C | ± 0.04% | ± 0.03% | 0.05 mm | 2.0 mV/V | 1.5 kg | Drawing |
| 1110 | ±25 / ±50 kN | T&C | ± 0.04% | ± 0.04% | 0.10 mm | 4.0 mV/V | 3.3 kg | Drawing |
| 1111 | 0-5 / 0-10 kN | Compression | ± 0.03% | ± 0.02% | 0.05 mm | 2.0 mV/V | 1.5 kg | Drawing |
| 1111 | 0-25, 0-50 kN | Compression | ± 0.04% | ± 0.04% | 0.10 mm | 2.0 mV/V | 3.3 kg | Drawing |
| 1120 | ±100 / ±250 kN | T&C | ± 0.04% | ± 0.04% | 0.10 mm | 4.0 mV/V | 9.8 kg | Drawing |
| 1121 | 0-100 / 0-250 kN | Compression | ± 0.04% | ± 0.04% | 0.10 mm | 4.0 mV/V | 9.8 kg | Drawing |
| 1132 | ±450 kN | T&C | ± 0.04% | ± 0.04% | 0.15 mm | 4.0 mV/V | 24 kg | Drawing |
| 1140 | ±900 kN | T&C | ± 0.06% | ± 0.06% | 0.20 mm | 4.0 mV/V | 66 kg | Drawing |
Installation
- Bridge supply: 1-20 VDC

- Installation 1: Tension only. The load is applied via swivel + nut. Sensor installation with base plate when the mounting surface has imperfections (see accessories). Screw types, tightening torques here
- Installation 2: Compression only. The load is applied to the measurement surface. Sensor installation with base plate when the mounting surface has imperfections (see accessories). Screw types, tightening torques here
- Installation 3: Tension/compression. The load is applied via a threaded rod + nut. Sensor installation directly on the surface. Screw types, tightening torques here
- Installation 4: Compression only. The load is applied to the measurement surface. Sensor installation directly on the surface. Screw types, tightening torques here
- Installation 5: Tension/compression, in-line, with base plates and swivels on both sides of the sensor. Screw types, tightening torques here
Detailed installation instructions here
ISO-376 Version
The 1100 series is also available with ISO-376 calibration. The range includes 4 models:
| Model | Ranges | Non-linearity | Hysteresis | Deflection | Output | Weight | Drawing |
|---|---|---|---|---|---|---|---|
| 1110ENF-5kN | ±5 / ±10 kN | ± 0.04% | ± 0.03% | 0.05 mm | 2.0 mV/V | 1.5 kg | Drawing |
| 1110ENH-25kN | ±25 / ±50 kN | ± 0.04% | ± 0.04% | 0.10 mm | 4.0 mV/V | 3.3 kg | Drawing |
| 1120ENJ-50kN | 0-5 / 0-10 kN | ± 0.03% | ± 0.02% | 0.05 mm | 2.0 mV/V | 1.5 kg | Drawing |
| 1120ENK-5kN | 0-25, 0-50 kN | ± 0.04% | ± 0.04% | 0.10 mm | 2.0 mV/V | 3.3 kg | Drawing |
Signal Conditioning and Acquisition
The output signal of the 1100 series sensors is unamplified. It is possible to obtain a complete measurement chain, wired and configured specifically for the application, by integrating a Display, an Analog signal conditioner/amplifier with voltage or current output, or a Data acquisition system for PC or PLC with included acquisition software. For more information, contact us.
Applications
- Test benches in aeronautics, automotive
- Material testing
- Test bench instrumentation
- Hydraulic cylinder instrumentation
- Sensor verification
- Calibration benches
Options and Accessories
- Type
- pancake, Reference load cell
- Measuring Range
- 1.5kN , 2.5kN , 5kN , 10kN , 25kN , 100kN , 450kN , 900kN , 50kN , 250kN
- Precision (max error)
- ≤ 0.1 %
- Nonlinearity (% FS)
- ± 0.03 %
- Hysteresis
- 0.02 % FS
- Nonrepeatability
- 0.01 % FS
- Zero Balance
- 0.0007 %PE/°C
- Sensibilité du gain
- 0.0015 %/°C
- Output Signal
- 2 mV/V
- Résistance du pont
- 350 Ω
- Tension d'alimentation
- 10 Vcc
- Measurement direction
- Traction & Compress.
- Surcharge
- 150 %PE
- Housing
- Aluminium
- Protection Class
- IP64
- Measuring Range (Force)
- 1 - 100 kN, 100 - 250 kN, > 250 kN
- Application
- High Accuracy, OEM
Dimensions 1110, 1120, 1132, 1140

Dimensions 1111, 1121

Connectors

| Bayonet Connector | Screw-on Connector | Cable Output (3m) |
|---|---|---|
![]() |
![]() |
![]() |
| Connector PT02E-10-6P / Option ACK or CDS | Connector PC04E-10-6P / Option AF or ALD | Option AJ |
Double or triple
According to standard
ISO 17025 or E74 NIST

| 1110 | 1110 | 1111 | 1111 | 1120 | 1121 | 1132 | 1140 |
|---|---|---|---|---|---|---|---|
| B101(M) | B102(M) | B101 | B102 | B103(M) | B103 | B112(M) | B105(M) |

Visualization of measurement in engineering units, alarm management, display of max-min values.
Output: ±5 VDC, ±10 VDC, 0-10 VDC, or 4-20 mA.
Transmission of measurement signals to a PC, programmable logic controller, recorder, or SCADA-type supervision application. Post-processing of measurement data via Excel or Matlab.