Precision Compression Force Sensor - 0-450 kN
- High-precision compression force sensor
- Measurement range: 0-450 kN
- Non-linearity: ±0.05%
- Repeatability: ± 0.01%
- Insensitive to transverse forces
- Deflection: 76 µm
- Temperature sensitivity < 0.0015% / °C
- Compression measurement only
- Overload protection: 150%
- Output signal: 4 mV/V
- Operating temperature: -55 to 90°C
- Double or triple bridge optional
- View the compression sensor range
Download the product datasheet
Overview
High-capacity, high-performance compression sensor
The compression sensor model 1331 offers a static accuracy of +/-0.07% or better in a compact design. The 1331 has a high output signal of 4 mV/V and its design compensates for eccentric loads to ensure maximum precision during measurements. The model 1331 is available in a 0-450 kN capacity. Overload protection is 150%.
The operating temperature range is -55 to 90°C. Temperature compensation is applied between -10 and 45°C.
Specifications

Dimensions

Installation
- Bridge supply: 1-20 VDC

-
Mounting 2: Compression only. The load is applied to the measurement surface. Sensor installation with base plate when the installation surface has imperfections (see accessories). Screw types, tightening torques here
-
Mounting 4: Compression only. The load is applied to the measurement surface. Sensor installation directly on the surface. Screw types, tightening torques here
Detailed mounting instructions here
Conditioning and acquisition
The output signal of the 1331 is unamplified. It is possible to obtain a complete measurement chain, wired and configured specifically for the application, by integrating, for example:
| Display 9840 | GSV-2TSDI | GSV-3USB | PMI-520AJ |
|---|---|---|---|
| Precision digital display for reference sensor | 24-bit display with acquisition function | USB acquisition module | Precision analog conditioner with voltage or current output |
Applications
- Test benches in aeronautics and automotive
- Material testing
- Test bench instrumentation
- Hydraulic cylinder instrumentation
- Sensor verification
- Calibration benches
Options and accessories
- Type
- pancake
- Precision (max error)
- ≤ 0.1 %
- Nonlinearity (% FS)
- ± 0.05 %
- Hysteresis
- 0.08 % FS
- Nonrepeatability
- 0.01 % FS
- Temperature Compensated Range
- -10 to 45 °C
- Operating temperature range
- -55 to 90 °C
- Zero Balance
- 0.0015 %PE/°C
- Sensibilité du gain
- 0.0015 %/°C
- Analog output signal
- non-amplifié
- Output Signal
- 4 mV/V
- Résistance du pont
- 350 Ω
- Tension d'alimentation
- 10 Vcc
- Measurement direction
- Compression
- Surcharge
- 150 %PE
- Housing
- Steel
- Protection Class
- IP40
- Measuring Range (Force)
- > 250 kN
- Application
- High Accuracy
Dimensions

Connectors


Double or triple
The full-scale signal is adjusted to its nominal value with very low tolerance
According to standard
ISO 17025 or ASTM74
Specific operating or compensation temperature range
Specific calibration range

Measurement visualization in engineering units, alarm management, max-min value display.
Output ±5 VDC, ±10 VDC, 0-10 VDC or 4-20 mA.
Transmission of measurement signals to a PC, programmable logic controller, recorder, or SCADA-type supervision application. Post-processing of measurement data via Excel or Matlab.